公司旗下E歐洲備件采購(gòu)網(wǎng)*三零服務(wù):零起訂量+零中間環(huán)節(jié)+*=內(nèi)專業(yè)的歐洲備件采購(gòu)服務(wù)!

XNX-AMSV-NNCB1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO,

 

4 x M25 entries, painted 316SS, includes MPD catalytic sensor  0-100%LEL

XNX-AMSV-NHCB1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,

 

ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD catalytic

 

sensor 0-100%LEL

XNX-AMSV-RNCB1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/

 

IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD catalytic

 

sensor 0-100%LEL

XNX-AMSV-RHCB1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local

 

HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS,

 

includes MPD catalytic sensor 0-100%LEL

XNX-AMSV-MNCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/

 

INMETRO, 4 x M25 entries, painted 316SS, includes MPD catalytic sensor

 

0-100%LEL

XNX-AMSV-MHCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes

 

MPD catalytic sensor 0-100%LEL

XNX-AMSV-FNCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,

 

ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD catalytic

 

sensor 0-100%LEL

XNX-AMSV-FHCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and

 

local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted

 

316SS, includes MPD catalytic sensor 0-100%LEL

XNX-AMAV-RNCB1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/

 

IECEx/INMETRO, 4 x M25 entries, painted aluminium, includes MPD catalytic

 

sensor 0-100%LEL

XNX-AMAV-RHCB1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and

 

local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted

 

aluminium, includes MPD catalytic sensor  0-100%LEL

XNX-AMAV-MNCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/

 

INMETRO, 4 x M25 entries, painted aluminium, includes MPD catalytic sensor

 

0-100%LEL

XNX-AMAV-MHCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted aluminium,

 

includes MPD catalytic sensor 0-100%LEL

XNX-AMAV-FNCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,

 

ATEX/IECEx/INMETRO, 4 x M25 entries, painted aluminium, includes MPD

 

catalytic sensor 0-100%LEL

XNX-AMAV-FHCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and

 

local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted

 

aluminium, includes MPD catalytic sensor  0-100%LEL

XNX-AMSV-NNIF1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO,

 

4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane)

 

sensor 0-100%LEL

XNX-AMSV-NHIF1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface

 

port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR

 

hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMSV-RNIF1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays,

 

ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR

 

hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMSV-RHIF1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local

 

HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS,

 

includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMSV-MNIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/

 

INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon

 

(Propane) sensor 0-100%LEL

XNX-AMSV-MHIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes

 

MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMSV-FNIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,

 

ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR

 

hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMSV-FHIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and

 

local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted

 

316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMAV-NNIF1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO,

 

4 x M25 entries, painted aluminium, includes MPD IR hydrocarbon (Propane)

 

sensor 0-100%LEL

XNX-AMAV-NHIF1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,

 

ATEX/IECEx/INMETRO, 3 x M25 entries, painted aluminium, includes MPD IR

 

hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMAV-RNIF1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays,

 

ATEX/IECEx/INMETRO, 4 x M25 entries, painted aluminium, includes MPD IR

 

hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMAV-RHIF1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and

 

local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted

 

aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMAV-MNIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/

 

INMETRO, 4 x M25 entries, painted aluminium, includes MPD IR hydrocarbon

 

(Propane) sensor 0-100%LEL

XNX-AMAV-MHIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted aluminium,

 

includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMAV-FNIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,

 

ATEX/IECEx/INMETRO, 4 x M25 entries, painted aluminium, includes MPD IR

 

hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMAV-FHIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and

 

local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted

 

aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMSV-NNIV1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO,

 

4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane)

 

sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-NHIV1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface

 

port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR

 

hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-RNIV1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays,

 

ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR

 

hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-RHIV1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local

 

HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS,

 

includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-MNIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/

 

INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon

 

(Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-MHIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes

 

MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-FNIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,

 

ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR

 

hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-FHIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and

 

local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted

 

316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-NNIV1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO,

 

4 x M25 entries, painted aluminium, includes MPD IR hydrocarbon (Methane)

 

sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-NHIV1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,

 

ATEX/IECEx/INMETRO, 3 x M25 entries, painted aluminium, includes MPD IR

 

hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-RNIV1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays,

 

ATEX/IECEx/INMETRO, 4 x M25 entries, painted aluminium, includes MPD IR

 

hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-RHIV1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and

 

local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted

 

aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-

 

5%v/v)

XNX-AMAV-MNIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/

 

INMETRO, 4 x M25 entries, painted aluminium, includes MPD IR hydrocarbon

 

(Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-MHIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted aluminium,

 

includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-FNIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,

 

ATEX/IECEx/INMETRO, 4 x M25 entries, painted aluminium, includes MPD IR

 

hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-FHIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and

 

local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted

 

aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-

 

5%v/v)

XNX-AMSV-NNIC1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO,

 

4 x M25 entries, painted 316SS, includes MPD IR CO2 sensor  0-5%v/v

XNX-AMSV-NHIC1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,

 

ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR CO2

 

sensor 0-5%v/v

XNX-AMSV-RNIC1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/

 

IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR CO2

 

sensor 0-5%v/v

XNX-AMSV-RHIC1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local

 

HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS,

 

includes MPD IR CO2 sensor 0-5%v/v

XNX-AMSV-MNIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/

 

INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR CO2 sensor

 

0-5%v/v

XNX-AMSV-MHIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes

 

MPD IR CO2 sensor 0-5%v/v

XNX-AMSV-FNIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,

 

ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR CO2

 

sensor 0-5%v/v

XNX-AMSV-FHIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and

 

local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted

 

316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMAV-NNIC1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO,

 

4 x M25 entries, painted aluminium, includes MPD IR CO2 sensor  0-5%v/v

XNX-AMAV-NHIC1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,

 

ATEX/IECEx/INMETRO, 3 x M25 entries, painted aluminium, includes MPD IR

 

CO2 sensor 0-5%v/v

XNX-AMAV-RNIC1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/

 

IECEx/INMETRO, 4 x M25 entries, painted aluminium, includes MPD IR CO2

 

sensor 0-5%v/v

XNX-AMAV-RHIC1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and

 

local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted

 

aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMAV-MNIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/

 

INMETRO, 4 x M25 entries, painted aluminium, includes MPD IR CO2 sensor

 

0-5%v/v

XNX-AMAV-MHIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted aluminium,

 

includes MPD IR CO2 sensor 0-5%v/v

XNX-AMAV-FNIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,

 

ATEX/IECEx/INMETRO, 4 x M25 entries, painted aluminium, includes MPD IR

 

CO2 sensor 0-5%v/v

XNX-AMAV-FHIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and

 

local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted

 

aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTSV-NNCB1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries,

 

painted 316SS, includes MPD catalytic sensor  0-100%LEL

XNX-UTSV-NHCB1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,

 

UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD catalytic  sensor

 

0-100%LEL

XNX-UTSV-RNCB1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/

 

CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD catalytic sensor

 

0-100%LEL

XNX-UTSV-RHCB1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local

 

HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes

 

MPD catalytic sensor 0-100%LEL

XNX-UTSV-MNCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA,

 

4 x 3/4"NPT entries, painted 316SS, includes MPD catalytic sensor  0-100%LEL

XNX-UTSV-MHCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes  MPD

 

catalytic sensor 0-100%LEL

XNX-UTSV-FNCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,

 

UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD catalytic  sensor

 

0-100%LEL

XNX-UTSV-FHCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output

 

and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS,

 

includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-NNCB1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries,

 

painted aluminium, includes MPD catalytic sensor  0-100%LEL

XNX-UTAV-NHCB1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface

 

port, UL/CSA, 3 x 3/4"NPT entries, painted aluminium, includes MPD  catalytic

 

sensor 0-100%LEL

XNX-UTAV-RNCB1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/

 

CSA, 4 x 3/4"NPT entries, painted aluminium, includes MPD catalytic  sensor

 

0-100%LEL

XNX-UTAV-RHCB1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and

 

local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted  aluminium,

 

includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-MNCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA,

 

4 x 3/4"NPT entries, painted aluminium, includes MPD catalytic  sensor

 

0-100%LEL

XNX-UTAV-MHCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, UL/CSA, 3 x 3/4"NPT entries, painted aluminium, includes  MPD

 

catalytic sensor 0-100%LEL

XNX-UTAV-FNCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/

 

CSA, 4 x 3/4"NPT entries, painted aluminium, includes MPD catalytic  sensor

 

0-100%LEL

XNX-UTAV-FHCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and

 

local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted  aluminium,

 

includes MPD catalytic sensor 0-100%LEL

XNX-UTSV-NNIF1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries,

 

painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTSV-NHIF1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,

 

UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon

 

(Propane) sensor 0-100%LEL

XNX-UTSV-RNIF1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/

 

CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon

 

(Propane) sensor 0-100%LEL

XNX-UTSV-RHIF1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local

 

HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes

 

MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTSV-MNIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA,

 

4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Propane)

 

sensor 0-100%LEL

XNX-UTSV-MHIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR

 

hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTSV-FNIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,

 

UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon

 

(Propane) sensor 0-100%LEL

XNX -UTSV-FHIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output

 

and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS,

 

includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-NNIF1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries,

 

painted aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-NHIF1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,

 

UL/CSA, 3 x 3/4"NPT entries, painted aluminium, includes MPD IR  hydrocarbon

 

(Propane) sensor 0-100%LEL

XNX-UTAV-RNIF1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays,

 

UL/CSA, 4 x 3/4"NPT entries, painted aluminium, includes MPD IR  hydrocarbon

 

(Propane) sensor 0-100%LEL

XNX-UTAV-RHIF1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and

 

local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted  aluminium,

 

includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-MNIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA,

 

4 x 3/4"NPT entries, painted aluminium, includes MPD IR  hydrocarbon

 

(Propane) sensor 0-100%LEL

XNX-UTAV-MHIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, UL/CSA, 3 x 3/4"NPT entries, painted aluminium, includes  MPD

 

IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-FNIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/

 

CSA, 4 x 3/4"NPT entries, painted aluminium, includes MPD IR hydrocarbon

 

(Propane) sensor 0-100%LEL

XNX-UTAV-FHIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and

 

local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted  aluminium,

 

includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTSV-NNIV1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries,

 

painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL

 

(0-5%v/v)

XNX-UTSV-NHIV1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,

 

UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon

 

(Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTSV-RNIV1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays,

 

UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon

 

(Methane) sensor 0-100%LEL (0-5%v/v)專業(yè)銷售霍尼韋爾 XNX Universal 變送器

XNX-UTSV-RHIV1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local

 

HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes

 

MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTSV-MNIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA,

 

4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Methane)

 

sensor 0-100%LEL (0-5%v/v)

XNX-UTSV-MHIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR

 

hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTSV-FNIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,

 

UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon

 

(Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTSV-FHIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output

 

and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS,

 

includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-NNIV1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT

 

entries, painted aluminium, includes MPD IR hydrocarbon (Methane) sensor

 

0-100%LEL (0-5%v/v)

XNX-UTAV-NHIV1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,

 

UL/CSA, 3 x 3/4"NPT entries, painted aluminium, includes MPD IR  hydrocarbon

專業(yè)銷售霍尼韋爾 XNX Universal 變送器

(Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-RNIV1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays,

 

UL/CSA, 4 x 3/4"NPT entries, painted aluminium, includes MPD IR  hydrocarbon

 

(Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-RHIV1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and

 

local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted  aluminium,

 

includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-MNIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA,

 

4 x 3/4"NPT entries, painted aluminium, includes MPD IR  hydrocarbon

 

(Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-MHIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, UL/CSA, 3 x 3/4"NPT entries, painted aluminium, includes  MPD

 

IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-FNIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/

 

CSA, 4 x 3/4"NPT entries, painted aluminium, includes MPD IR hydrocarbon

 

(Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-FHIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and

 

local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted  aluminium,

 

includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTSV-NNIC1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries,

 

painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTSV-NHIC1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,

 

UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR CO2 sensor

 

0-5%v/v

XNX-UTSV-RNIC1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays,

 

UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR CO2 sensor

 

0-5%v/v

XNX-UTSV-RHIC1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local

 

HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes

 

MPD IR CO2 sensor 0-5%v/v

XNX-UTSV-MNIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA,

 

4 x 3/4"NPT entries, painted 316SS, includes MPD IR CO2 sensor  0-5%v/v

XNX-UTSV-MHIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR

 

CO2 sensor 0-5%v/v

XNX-UTSV-FNIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,

 

UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR CO2 sensor

 

0-5%v/v

XNX-UTSV-FHIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output

 

and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS,

 

includes MPD IR CO2 sensor 0-5%v/v

XNX-UTAV-NNIC1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries,

 

painted aluminium, includes MPD IR CO2 sensor  0-5%v/v

XNX-UTAV-NHIC1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,

 

UL/CSA, 3 x 3/4"NPT entries, painted aluminium, includes MPD IR CO2 sensor

 

0-5%v/v

XNX-UTAV-RNIC1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/

 

CSA, 4 x 3/4"NPT entries, painted aluminium, includes MPD IR CO2 sensor

 

0-5%v/v

XNX-UTAV-RHIC1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and

 

local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted  aluminium,

 

includes MPD IR CO2 sensor 0-5%v/v

XNX-UTAV-MNIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x

 

3/4"NPT entries, painted aluminium, includes MPD IR CO2 sensor  0-5%v/v

XNX-UTAV-MHIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®

 

interface port, UL/CSA, 3 x 3/4"NPT entries, painted aluminium, includes  MPD

 

IR CO2 sensor 0-5%v/v

XNX-UTAV-FNIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/

 

CSA, 4 x 3/4"NPT entries, painted aluminium, includes MPD IR CO2 sensor

 

0-5%v/v

XNX-UTAV-FHIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and

 

local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted  aluminium,

 

includes MPD IR CO2 sensor 0-5%v/v

Part Number

DeSCRJPTion

MPD-AMCB1

XNX MPD Sensor, M25, ATEX/IECEx/INMETRO, Catalytic Bead, Flammables (Methane Cal) 0-100%LEL

MPD-AMIF1

XNX MPD Sensor, M25, ATEX/IECEx/INMETRO, IR Hydrocarbons (Propane Cal)  0-100%LEL

MPD-AMIV1

XNX MPD Sensor, M25, ATEX/IECEx/INMETRO, IR Methane 0-100%LEL or

0-500% v/v

MPD-AMIC1

XNX MPD Sensor, M25, ATEX/IECEx/INMETRO, IR Carbon Dioxide 0-500%v/v

MPD-UTCB1

XNX MPD Sensor, 3/4""NPT, UL/CSA, Catalytic Bead, Flammables (Methane Cal) 0-100%LEL

MPD-UTIF1

XNX MPD Sensor, 3/4"NPT, UL/CSA, IR Hydrocarbons (Propane Cal) 0-100%LEL

MPD-UTIV1

XNX MPD Sensor, 3/4"NPT, UL/CSA, IR Methane 0-100%LEL or 0-500% v/v

MPD-UTIC1

XNX MPD Sensor, 3/4"NPT, UL/CSA, IR Carbon Dioxide 0-500%v/v

1226A0359

XNX MPD Cartridge, Catalytic Bead, Flammables (Methane Cal) 0-100%LEL

1226-0300

XNX MPD Cartridge, IR Hydrocarbons (Propane Cal) 0-100%LEL

1226-0299

XNX MPD Cartridge, IR Methane 0-100%LEL or 0-5.00% Vol.

1226-0301

XNX MPD Cartridge, IR Carbon Dioxide 0-5.00%Vol.

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
北京志鴻恒拓科技有限公司

北京志鴻恒拓科技有限公司

地址:北京市朝陽區(qū)建國(guó)路88號(hào)soho現(xiàn)代城

© 2025 版權(quán)所有:北京志鴻恒拓科技有限公司  備案號(hào):京ICP備16029562號(hào)-5  總訪問量:671593  sitemap.xml  技術(shù)支持:化工儀器網(wǎng)  管理登陸

国产成人久久久一区二区| 亚洲av乱码一区二区三区| 2017亚洲天堂a在线| 国产黄色精品一区二区三区| 一本一道久久a久久精品综合| 精品九九99久久免费九九| 无码人妻精品区二区三区| 第4色奇米26在线观看| 精品久久久久久无码人妻| 亚洲精品成人av一区二区| 午夜精品视频免费在线观看| 久久黑丝袜诱惑女一区精品| 亚洲av无码一区二区二三区软件| 免费在线看污的视频网站| 久久久久久精品成人网站| 99热这里只有的精品8| 综合色区亚洲熟妇另类a| 99久在线精品99re8| 成人av在线播放亚洲高清| 久久久久久久久国产免费| 精品国产一区二区999| 日本特黄大片国产精品。| 亚洲国产精品无码中文在线| 611国产精品中文字幕| 99蜜桃一区二区三区麻豆| 色综合久久久久无码专区| 国产精品免费区在线高清| 国产亚洲精久久久久久婷婷| 亚洲中文久久久精品无码| 成人精品自拍小视频在线| 自拍偷自拍亚洲精品电影| 欧美大尺度视频一区二区| 中文无码日韩欧免费视频| 巴巴在线电影| 99热这里只有精品九九9| 白丝袜美女脚交国产精品| 久久一区二区av免费观看| 天天操天天舔天天操天天舔| 精品人妻少妇久久蜜臀av| 国产熟女一区二区三区五月婷| 婷婷久久精品国产一区二区|